Moore Industries: The Interface Solution Experts MooreHawke: Fieldbus Interface Solutions
Product Information
Distributed I/O and Data Communication Systems
E-Help Express: Click Here First
Main Product Selection Index
Data Sheet Library
Installation Manual Library
CAD Drawing Library
Certifications & Safety-Related Instrumentation
Problem Solvers Application Notes
Add me to Email Technology Update List
Site Map
Chinese Web Site
Distributed I/O and Data Communication Systems Eliminate expensive point-to-point wires by sending just a few—or thousands of—process monitoring and control signals between the field and control room on one digital communication link.

For more information, go to Problem Solvers Application Ideas and Capabilities.

Detailed product data sheets are available in PDF format by clicking on the product names below. PDF files require Adobe Reader, which can be downloaded free from Adobe's Web site.

USB Cable Now Available for PC-Programmable Interface Instruments!
In addition to our FREE serial Configuration Cable, we now offer (for a nominal charge) a USB Communication Cable for Moore Industries' PC-Programmable Instruments. Get Data Sheet (535K)

Featured Interface Solutions
Model Input Output Power Mounting
NCS NET Concentrator System®  Process Control and Distributed I/O System

NCS NET Concentrator System <SUP>®</SUP>

Get Data Sheet
ncs.pdf (1.1M )

Get Distributed I/O Problem Solver Application Notes

Get Overview Presentation
NCS_Overview_03_03.pdf (1.2M )

Get Interactive Presentation
NCS Ready for the Real World (2.1M )

  • 10/100Base-T Ethernet or MODBUS (RS-485) Networks
  • Configures over the internet (Ethernet model)
  • Just four, or thousands, of I/O points per network
  • Mixed analog and digital I/O
  • Peer-to-Host and Peer-to-Peer Networks
  • 20-bit resolution
  • Advanced math functions, PID control, and data logging
Universal and Modular I/O Blocks Program Over the Web (Ethernet Models) or Using PC Software (MODBUS Models)
Current
Any range from 0 to 20mA including:
0-20mA
4-20mA
Voltage
Any range from -10 to 10Vdc including:
1-5Vdc
0-10Vdc
-10-10Vdc

RTD
2-, 3-, 4-Wire
100-1000ohm
Platinum, Nickel and Copper
Thermocouple
J, K, E, T, R, S, B, N, C
Potentiometer
100-1000ohms
Millivolts
-50-1000mV

Communication Link
Ethernet
MODBUS RTU (RS-485)


NET Concentrator System are registered trademarks of Moore Industries-International, Inc.
Universal and Modular I/O Blocks Program Over the Web (Ethernet Models) or Using PC Software (MODBUS Models)
Current
Any range from 0-20mA including:
0-20mA
4-20mA
Voltage
Any range from 0-10Vdc including:
1-5Vdc
0-10Vdc

Discrete
High/Low
Open/Close
On/Off

Relay

Communication Link
Ethernet
MODBUS RTU (RS-485)
4-Wire, Line-Powered (20-30Vdc) Modular
DIN-style (G-type and Top Hat rails)
MNCS  microNCS® MODBUS RTU Master and Distributed I/O System

MNCS microNCS<SUP>®</SUP> MODBUS RTU Master and Distributed I/O System

Get Data Sheet
mncs.pdf ( 687K )

Standard 4 or 8 Input Channels Individually Program Over the Web
4-20mA

Expandable with NCS NET Concentrator System® Expansion I/O Modules for Voltage, RTD Thermocouple and Discrete Inputs, and Relay Outputs

Standard 4 Discrete (Contact Closure) Inputs

Optional Dial-Up Modem for Programming and Monitoring Inputs and Outputs
Standard Communication Links per Module
Dual MODBUS RTU (RS-485) Ports
One Ethernet Port

4-Wire, Line-Powered
(20-30Vdc)
Universal for any range between 90-260Vac

Modular
DIN-style (G-type and Top Hat rails)


Get Data Sheet
wlm.pdf (284K)

Get Wireless Possibilities
White Paper

wireless_possibilities.pdf (190K )

NET Concentrator System® Goes Wireless!
When wires can't be run for practical or economic reasons, our Wireless Link Module (Model WLM) provides accurate and reliable wireless connectivity between remote field sites. A bi-directional, spread spectrum radio modem, the WLM is ideal for use with Moore Industries' NET Concentrator System, and with similar distributed I/O systems, to overcome rugged, long-distance or normally impassable environments. You can send just a few, or thousands of, process signals over one low-cost wireless communication link.

  • Highly reliable Intelligent Spectrum Frequency Hopping Technology
  • Standard operating frequencies of 902-928MHz and 2.4-2.483GHz
  • Long distance transmission of up to 25 miles
  • Supports Ethernet and serial communications
  • FCC site license is not required
  • User configurable operating parameters
 
CPMS  Cathodic Protection Monitoring System

Cathodic Protection Monitoring System

Get Data Sheet
cpms.pdf ( 498K )

Standard 4 or 8 Cathodic Protection Monitoring Channels Individually Rangeable Over the Web
0-100Vdc
0-100mV
-5 to +5Vdc
4-20mA

Expandable with NCS NET Concentrator System® Expansion I/O Modules for Voltage, RTD, Thermocouple and Discrete Inputs, and Relay Inputs

Standard 4 Discrete (Contact Closure) Inputs

Optional Dial-Up Modem for Programming and Monitoring Inputs and Outputs
Standard Communication Links per Module
Dual MODBUS RTU (RS-485) Ports
One Ethernet Port

4-Wire, Line-Powered
(20-30Vdc)
Universal for any range between 90-260Vac

Modular
DIN-style (G-type and Top Hat rails)
I/O EQUATION STATION® Multifunction Distributed I/O System

I/O Equation Station

Get Data Sheet
mds.pdf (362K )

  • Configurable math functions
  • Mixed analog and digital I/O
  • Up to 4 inputs and 4 outputs
  • Up to 1,016 points per network
  • No special programming language
  • Compatible with MMI software
Multiple Channels are PC-Programmable
Current/Voltage
0-25mA
-10 to 10 Vdc
-625 to +625mV
RTD
2-, 3-, 4-Wire; Platinum, Nickel, and Copper
Thermocouple
J, K, E, T, R, S, B, N, U, L
Bridge Potentiometer Resistance

Digital
High/Low Status
Frequency
Pulse or Up/Down Counter

RS-485 COMM Link
MODBUS RTU
PROFIBUS
Multiple Channels are PC-Programmable
Analog
0-20mA

Digital
Host Controlled
Process Controlled

RS-485 COMM Link
MODBUS RTU
PROFIBUS
4-Wire,
Line-Powered
(10-30Vdc)
Thermoplastic,
DIN-style
(Top Hat rail)
CCS® Cable Concentrator System®

CCS

Get Data Sheet
ccs.pdf (361K )

  • On-board, real-time process display
  • Mixed analog and digital I/O
  • 16 channels per module
  • Peer-to-peer and peer-to-host
Selectable with On-Board Controls
Input Module
Analog
0-20mA
0-10Vdc
Discrete
High/Low
Open/Close
On/Off

Output Module
RS-485 COMM Link
Proprietary for peer-to-peer systems

MODBUS RTU for peer-to-host systems
Selectable with On-Board Controls
Output Module
Analog
0-20mA
0-10Vdc
Discrete
High/Low
Open/Close
On/Off
Relay

Input Module
RS-485 COMM Link
Proprietary for peer-to-peer systems

MODBUS RTU for peer-to-host systems
4-Wire,
Line-Powered
(18-30Vdc)
High-Density
Aluminum
DIN-style
(G-type and Top Hat rails)
I/O EXPRESS Distributed Data System®

I/O Express

Get Data Sheet
dds.pdf (1.0M )

  • Direct RTD and T/C inputs
  • Up to 7,812 points per system
  • Up to 21 channels per I/O brick
  • Peer-to-peer and peer-to-host
  • Master/slave and masterless
Current/Voltage
4-20mA
0-2Vdc
0-5Vdc
0-10Vdc
RTD
3-wire Platinum
Thermocouple
J and K
Discrete

RS-485 COMM Link
MODBUS RTU
Current/Voltage
4-20mA
Discrete
Relay

RS-485 COMM Link
MODBUS RTU
4-Wire,
Line-Powered
(11-30Vdc)
Thermoplastic,
DIN-style
(Top Hat rail)
Complementary Distributed I/O and Data Communication Systems Accessories
Ethernet Switches (Switching Hubs)
Intelligent multi-port communications switches automatically determine and remember where a NET Concentrator System® Station is located, and routs messages only through the appropriate port to that Station. This minimizes network loading and improves deterministic communications over Ethernet.

Ethernet Hubs
Enables multiple NET Concentrator System® stations or other compatible devices to be connected on a common Ethernet data link.

Ethernet Routers
Connects multiple NET Concentrator System® segments or sub-networks, forwards messages from one network to another, and provides message traffic isolation between segments.

RS-485 to RS-232C/RS-422 Converter
For MODBUS (RS-485) networks, converts the RS-485 signal to either RS-232C or RS-422 standard to allow direct interface with a modem or computer-based systems, such as a PC.

RS-485 Repeater
Extends a MODBUS-communicating system's allowable transmission distance an additional 10,000 feet over its limit.

 
 
  Wireless RF Modems
Where wires can't be run for practical or economic reasons, spread spectrum wirless radio (RF) communication provides accurate and reliable connectivity between sites. Distances between modems can be up to 20 miles, and repeaters can extend coverage even further.

Short Haul Modems
For MODBUS (RS-485) networks, the Short Haul Modem extends the a I/O system's allowable transmission distance to 10 miles (16km).

Dial-Up Modems
The Dial-Up (or Dedicated Modem) permits unlimited transmission distances over a regular switched telephone line or leased dedicated line.

Data Line (Surge) Protectors
Data Line (Surge) Protectors Mounts on a G-type rail next to the NCS to protect the data link from damaging voltage and current surges caused by lightning, welding, heavy electrical equipment, and switch gears.

Instrument Power Supplies
A complete line of instrument power supplies for mounting alongside and powering our Distributed I/O systems.

Redundant Power Supply
DIN-style, rail-mount module accepts two power supply inputs and provides an uninterrupted power source by passing the highest voltage.